According to the different uses of the iron core, our company can produce various types of iron cores such as laminated iron cores, three-phase three-dimensional wound iron cores, and amorphous alloy iron cores.

Transformers are manufactured based on the principle of electromagnetic induction,and the magnetic circuit is the medium for electrical energy conversion.

The iron core is the main magnetic circuit of the transformer, and its main function is to conduct magnetism. It converts the electrical energy of the primary circuit into magnetic energy, and then converts the magnetic energy into the electrical energy of the secondary circuit.

At the same time, the iron core is also the mechanical skeleton of the transformer. The clamping device of the iron core not only makes the magnetic conductor a complete mechanical structure, but also has insulated coils sleeved on it, supports the leads, and installs almost all the internal components of the transformer.

The iron core has the largest weight among all the components of the transformer. It accounts for about 60% of the total weight in dry-type transformers and about 40% in oil-immersed transformers.

 

ဖော်ပြချက်ကို ရိုက်ထည့်ပါ။

 

1.jpg

 

စွမ်းဆောင်ရည် parameter သည်

 

နံပါတျ စမ်းသပ်ပစ္စည်းများ စံသတ်မှတ်ချက်များ တကယ့်အချက်အလက်
1 ချုပ် ≤1.0mm 1.0mm
2 အဘယ်သူမျှမ - ဝန်အရှုံး PO≤553W 540W
3 Window diagonal ≤2.0mm 1.2mm
4 လျှပ်ကာခုခံ Iron core to ground insulation resistance 5MΩ Ω5MΩ
5 ပင်စည် Verticalltys(2/1000)mm s(2/1000)mm
Curvatures(1.5/1000)mm s(1.5/1000)mm
6 Lamination အထူ Main stage:60±1mm 60mm
Total stack thickness: 260±1mm 260mm
7 Window height and width Window height:317±1mm 317mm
Window width:185±1mm 185mm
8 Clamp sizo Strictly implemented in accordance with the technical agreement,non-standardclamps implemented in accordance with the national standard dimensionaltolerance (C-level roughness) လွန်
9 Laminated wood:32.5±0.5mmFoot insulation 32.5±0.5mmPressboard:6±0.5mm6±0.5mm 32.5mm
6mm
10 Standard part siz0 Strictly implemented in accordance with the technical agreement,non-standardparts implemented in accordance with the national standard dimensionaltolerance (C-level roughness) လွန်
11 ယေဘုယျအသွင်အပြင် Strictly implemented in accordance with the technical agreement,non-standard implemented in accordance with the national standard dimensionaltolerance(C-level roughness) လွန်

တစ်ဦးအခမဲ့ Quote Get

ကျွန်ုပ်တို့၏ ကိုယ်စားလှယ်သည် သင့်အား မကြာမီ ဆက်သွယ်ပေးပါမည်။
အီးမေးလ်လိပ်စာ
အမည်
ကုမ္ပဏီအမည်
ပြောဆိုမည့်အကြောင်းအရာ [Message]
0/1000
မေးခြင်း

တစ်ဦးအခမဲ့ Quote Get

ကျွန်ုပ်တို့၏ ကိုယ်စားလှယ်သည် သင့်အား မကြာမီ ဆက်သွယ်ပေးပါမည်။
အီးမေးလ်လိပ်စာ
အမည်
မိုဘိုင်း/WhatsApp
ကုမ္ပဏီအမည်
ပြောဆိုမည့်အကြောင်းအရာ [Message]
0/1000