- ျခံဳငံုသံုးသပ္မႈ
- အကြံပြုထုတ်ကုန်များ
The structural design of the dry-type transformer with second-level energy efficiency is advanced, and high-temperature insulation materials that are resistant to both sound and visual influence are adopted. It has the characteristics of good no-load energy consumption, safety and reliability, etc., ensuring a stable power output.
It is mainly used for the wiring of electrical circuits, electrical equipment and electromechanical equipment, providing stable power output quality for the power matching of various electrical and mechanical equipment.
It has a high insulation class and stable and reliable performance. In practical applications, it can provide continuous and stable high-quality voltage transformation services.
It has high working efficiency and can provide efficient power output to ensure the safe operation of the power supply.
It has good heat dissipation performance and excellent performance reliability during long-term operation.
စံနှုန်းများကို ကျင့်သုံးပါ။
GB 1094-2013 'ပါဝါထရန်စဖော်မာ'
GB/T 2900.95 လျှပ်စစ်ဆိုင်ရာ အသုံးအနှုန်းများ ထရန်စဖော်မာများ၊ ဗို့အားထိန်းညှိကိရိယာနှင့် ဓာတ်ပေါင်းဖိုများ
GB/T 10228 အခြောက်အမျိုးအစား powertransformers များ၏ နည်းပညာဆိုင်ရာ ကန့်သတ်ချက်များ နှင့် လိုအပ်ချက်များ
GB 20052-2020 ပါဝါထရန်စဖော်မာ စွမ်းအင်ထိရောက်မှု ကန့်သတ်ချက်တန်ဖိုးနှင့် စွမ်းအင်
IEC 60076 'ပါဝါထရန်စဖော်မာ'
ဖော်ပြချက်ကို ရိုက်ထည့်ပါ။
ပုံမှန်ဝန်ဆောင်မှုအခြေအနေ
အမြင့် 1000 မီတာအောက်
အမြင့်ဆုံးအပူချိန်မှာ +40 ဒီဂရီစင်တီဂရိတ်ဖြစ်သည်။
အမြင့်ဆုံးနေ့စဉ်ပျမ်းမျှအပူချိန်သည် +20 ဒီဂရီစင်တီဂရိတ်ဖြစ်သည်။
အနိမ့်ဆုံးပြင်ပအပူချိန်မှာ -20 ဒီဂရီစင်တီဂရိတ်ဖြစ်သည်။
စွမ်းဆောင်ရည် parameter သည်
အဆင့်သတ်မှတ်နိုင်မှု(kVA) | Electrical steel belt | Amorphous အလွိုင်း | Short-circuitimpedence(%) | ||||||
ဝန်မရှိခြင်း (W) | ဝန်ဆုံးရှုံးမှု(W) | ဝန်မရှိခြင်း (W) | ဝန်ဆုံးရှုံးမှု(W) | ||||||
B (100℃) | F(120℃) | H(145℃) | B(100℃) | F(120℃) | H(145℃) | ||||
30 | 130 | 605 | 640 | 685 | 60 | 605 | 640 | 685 | 4.0 |
50 | 185 | 845 | 900 | 965 | 75 | 845 | 900 | 965 | |
80 | 250 | 1160 | 1240 | 1330 | 100 | 1160 | 1240 | 1330 | |
100 | 270 | 1330 | 1415 | 1520 | 110 | 1330 | 1415 | 1520 | |
125 | 320 | 1565 | 1665 | 1780 | 130 | 1565 | 1665 | 1780 | |
160 | 365 | 1800 | 1915 | 2050 | 145 | 1800 | 1915 | 2050 | |
200 | 420 | 2135 | 2275 | 2440 | 170 | 2135 | 2275 | 2440 | |
250 | 490 | 2330 | 2485 | 2665 | 195 | 2330 | 2485 | 2665 | |
315 | 600 | 2945 | 3125 | 3355 | 235 | 2945 | 3125 | 3355 | |
400 | 665 | 3375 | 3590 | 3850 | 265 | 3375 | 3590 | 3850 | |
500 | 790 | 4130 | 4390 | 4705 | 305 | 4130 | 4390 | 4705 | |
630 | 910 | 4975 | 5290 | 5660 | 360 | 4975 | 5290 | 5660 | |
630 | 885 | 5050 | 5365 | 5760 | 350 | 5050 | 5365 | 5760 | 6.0 |
800 | 1035 | 5895 | 6265 | 6715 | 410 | 5895 | 6265 | 6715 | |
1000 | 1205 | 6885 | 7315 | 7885 | 470 | 6885 | 7315 | 7885 | |
1250 | 1420 | 8190 | 8720 | 9335 | 550 | 8190 | 8720 | 9335 | |
1600 | 1665 | 9945 | 10555 | 11320 | 645 | 9945 | 10555 | 11320 | |
2000 | 2075 | 12240 | 13005 | 14005 | 850 | 12240 | 13005 | 14005 | |
2500 | 2450 | 14535 | 15445 | 16605 | 1020 | 14535 | 15445 | 16605 |