Our company can produce this product with a voltage class range of 1-40.5kV and below.The KYN series switchgear is an armored withdrawable AC metal-enclosed switchgear. It is suitable for a three-phase AC 50Hz power system, used for receiving and distributing electrical energy, and implementing control, protection, and monitoring of the circuit.

The main models are KYN28A-12, KYN28A-24, and KYN61-40.5. It can be equipped with various indoor vacuum circuit breakers and can be installed with microcomputer protection as a combined electrical appliance to achieve remote measurement,remote control, remote signaling, and unattended operation. It is mainly used for power transmission of small and medium-sized generators in power plants, power distribution in industrial and mining enterprises, station service transformers in the power system,power distribution in high-rise commercial centers and residential areas, for implementing control, protection, and monitoring.

For the KYN28A-12 and KYN28A-24 series switchgear, the switchgear as a whole is composed of two major parts: the cabinet body and the center-mounted withdrawable components (i.e., the circuit breaker carriages). The cabinet body is divided into four separate compartments. The protection level of the outer shell is IP4X, and the protection level when the doors ofeach compartment and the circuit breaker compartment are open is IP2X.

It has overhead incoming and outgoing line, cable incoming and outgoing line,and other functional schemes. After being arranged and combined, it forms a complete set of power distribution system equipment. This switchgear can be installed,debugged, and maintained from the front. Therefore, it can be installed back-to-back, in double rows, and against the wall, which improves the safety and flexibility of the switchgear and reduces the occupied area.

 

စံချိန်စံညွှန်းများ ပြဋ္ဌာန်းပါ။

 

IEC 62271 《High Voltage Switchgear and Control Equipment》

GB/T11022 《High Voltage Switchgear and control equipment standard common technical requirements》

 

ဖော်ပြချက်ကို ရိုက်ထည့်ပါ။

 

1.jpg

 

ပုံမှန်ဝန်ဆောင်မှုအခြေအနေ

 

Ambient air temperature: -15℃~+40℃

Altitude: 1000m and below

Relative humidity: The daily average relative humidity is not more than 95%, and the monthly average relative humidity is not more than 90%.

Seismic intensity:Not exceeding 8 degrees

Places without fire, explosion hazards, serious pollution, chemical corrosion and severe vibration

 

စွမ်းဆောင်ရည် parameter သည်

 

အမည် ယူနစ် ဒေတာများ
Matched circuit breaker
ZN63A-12(VS1) VD4
rated ဗို့ KV 12 12
1min ပါဝါကြိမ်နှုန်းသည် ဗို့အားကိုခံနိုင်ရည်ရှိသည်။ kV 42 42
Rated impulse withstand volage(peak) kV 75 75
အဆင့်သတ်မှတ်ချက်ကြိမ်နှုန်း Hz 50 50
လက်ရှိအဆင့်သတ်မှတ်ချက် A 630,1250,1600,2000,2500,3150,4000,5000
Rated current of branch busbar A 630,1250,1600,2000,2500,3150,4000,5000
အချိန်တိုအတွင်း အဆင့်သတ်မှတ်ထားသော လက်ရှိ (virtual value) ကို ခံနိုင်ရည်ရှိသည်။ kA 16,20,25,31.5,40,50 16,20,25,31.5,40,50
အဆင့်သတ်မှတ်ထားသော အထွတ်အထိပ်သည် လက်ရှိကို ခံနိုင်ရည်ရှိသည်။ kA 40,50,63,80,100,125 40,50,63,80,100,125
ဝါယာရှော့ကာလကို အဆင့်သတ်မှတ်ထားသည်။ S 4
ကာကွယ်စောင့်ရှောက်မှုအဆင့်ကို The sell is IP4X and it is IP2X when the compartment door andhandcart door is opened
အလေးချိန် kg 700-1200 700-1200

တစ်ဦးအခမဲ့ Quote Get

ကျွန်ုပ်တို့၏ ကိုယ်စားလှယ်သည် သင့်အား မကြာမီ ဆက်သွယ်ပေးပါမည်။
အီးမေးလ်လိပ်စာ
အမည်
ကုမ္ပဏီအမည်
ပြောဆိုမည့်အကြောင်းအရာ [Message]
0/1000
မေးခြင်း

တစ်ဦးအခမဲ့ Quote Get

ကျွန်ုပ်တို့၏ ကိုယ်စားလှယ်သည် သင့်အား မကြာမီ ဆက်သွယ်ပေးပါမည်။
အီးမေးလ်လိပ်စာ
အမည်
မိုဘိုင်း/WhatsApp
ကုမ္ပဏီအမည်
ပြောဆိုမည့်အကြောင်းအရာ [Message]
0/1000