lahat ng kategorya
transformer assembly transformer core-0

Mga Bahagi ng Transformer

Home  >  Mga Produkto >  Mga Bahagi ng Transformer

Transformer assembly Transformer core

  • Pangkalahatang-ideya
  • Inirerekumendang Produkto

According to the different uses of the iron core, our company can produce various types of iron cores such as laminated iron cores, three-phase three-dimensional wound iron cores, and amorphous alloy iron cores.

Transformers are manufactured based on the principle of electromagnetic induction,and the magnetic circuit is the medium for electrical energy conversion.

The iron core is the main magnetic circuit of the transformer, and its main function is to conduct magnetism. It converts the electrical energy of the primary circuit into magnetic energy, and then converts the magnetic energy into the electrical energy of the secondary circuit.

At the same time, the iron core is also the mechanical skeleton of the transformer. The clamping device of the iron core not only makes the magnetic conductor a complete mechanical structure, but also has insulated coils sleeved on it, supports the leads, and installs almost all the internal components of the transformer.

The iron core has the largest weight among all the components of the transformer. It accounts for about 60% of the total weight in dry-type transformers and about 40% in oil-immersed transformers.

 

Paglalarawan ng uri

 

1.jpg

 

Parameter ng pagganap

 

Hindi. Mga item sa pagsusulit Mga karaniwang kinakailangan Aktwal na data
1 Pinagtahian ≤1.0mm 1.0mm
2 Walang pagkawala ng pag-load PO≤553W 540W
3 Window diagonal ≤2.0mm 1.2mm
4 Pagkakabukod paglaban Iron core to ground insulation resistance 5MΩ ≥5MΩ
5 tangkay Verticalltys(2/1000)mm s(2/1000)mm
Curvatures(1.5/1000)mm s(1.5/1000)mm
6 Lamination thickness Main stage:60±1mm 60mm
Total stack thickness: 260±1mm 260mm
7 Window height and width Window height:317±1mm 317mm
Window width:185±1mm 185mm
8 Clamp sizo Strictly implemented in accordance with the technical agreement,non-standardclamps implemented in accordance with the national standard dimensionaltolerance (C-level roughness) Ang pumasa sa
9 Laminated wood:32.5±0.5mmFoot insulation 32.5±0.5mmPressboard:6±0.5mm6±0.5mm 32.5mm
6mm
10 Standard part siz0 Strictly implemented in accordance with the technical agreement,non-standardparts implemented in accordance with the national standard dimensionaltolerance (C-level roughness) Ang pumasa sa
11 Pangkalahatang hitsura Strictly implemented in accordance with the technical agreement,non-standard implemented in accordance with the national standard dimensionaltolerance(C-level roughness) Ang pumasa sa

Kumuha ng isang Libreng Quote

Makikipag-ugnayan sa iyo ang aming kinatawan sa lalong madaling panahon.
Email
Pangalan
Pangalan ng Kumpanya
mensahe
0/1000
pagtatanong

Kumuha ng isang Libreng Quote

Makikipag-ugnayan sa iyo ang aming kinatawan sa lalong madaling panahon.
Email
Pangalan
Mobile / WhatsApp
Pangalan ng Kumpanya
mensahe
0/1000