Our company can produce this product with a voltage class range of 1-40.5kV and below.The KYN series switchgear is an armored withdrawable AC metal-enclosed switchgear. It is suitable for a three-phase AC 50Hz power system, used for receiving and distributing electrical energy, and implementing control, protection, and monitoring of the circuit.

The main models are KYN28A-12, KYN28A-24, and KYN61-40.5. It can be equipped with various indoor vacuum circuit breakers and can be installed with microcomputer protection as a combined electrical appliance to achieve remote measurement,remote control, remote signaling, and unattended operation. It is mainly used for power transmission of small and medium-sized generators in power plants, power distribution in industrial and mining enterprises, station service transformers in the power system,power distribution in high-rise commercial centers and residential areas, for implementing control, protection, and monitoring.

For the KYN28A-12 and KYN28A-24 series switchgear, the switchgear as a whole is composed of two major parts: the cabinet body and the center-mounted withdrawable components (i.e., the circuit breaker carriages). The cabinet body is divided into four separate compartments. The protection level of the outer shell is IP4X, and the protection level when the doors ofeach compartment and the circuit breaker compartment are open is IP2X.

It has overhead incoming and outgoing line, cable incoming and outgoing line,and other functional schemes. After being arranged and combined, it forms a complete set of power distribution system equipment. This switchgear can be installed,debugged, and maintained from the front. Therefore, it can be installed back-to-back, in double rows, and against the wall, which improves the safety and flexibility of the switchgear and reduces the occupied area.

 

Ipatupad ang mga pamantayan

 

IEC 62271 《High Voltage Switchgear and Control Equipment》

GB/T11022 《High Voltage Switchgear and control equipment standard common technical requirements》

 

Paglalarawan ng uri

 

1.jpg

 

Normal na kondisyon ng serbisyo

 

Ambient air temperature: -15℃~+40℃

Altitude: 1000m and below

Relative humidity: The daily average relative humidity is not more than 95%, and the monthly average relative humidity is not more than 90%.

Seismic intensity:Not exceeding 8 degrees

Places without fire, explosion hazards, serious pollution, chemical corrosion and severe vibration

 

Parameter ng pagganap

 

Pangalan Yunit data
Matched circuit breaker
ZN63A-12(VS1) VD4
Rated boltahe KV 12 12
1min kapangyarihan dalas makatiis boltahe kV 42 42
Rated impulse withstand volage(peak) kV 75 75
Rated na dalas Hz 50 50
Rated kasalukuyang A 630,1250,1600,2000,2500,3150,4000,5000
Rated current of branch busbar A 630,1250,1600,2000,2500,3150,4000,5000
Rated short-time withstand current (virtual value) kA 16,20,25,31.5,40,50 16,20,25,31.5,40,50
Rated na tugtog makatiis sa kasalukuyan kA 40,50,63,80,100,125 40,50,63,80,100,125
Na-rate ang tagal ng maikling circuit S 4
Level Protection The sell is IP4X and it is IP2X when the compartment door andhandcart door is opened
timbang kg 700-1200 700-1200

Kumuha ng isang Libreng Quote

Makikipag-ugnayan sa iyo ang aming kinatawan sa lalong madaling panahon.
Email
Pangalan
Pangalan ng Kumpanya
mensahe
0/1000
pagtatanong

Kumuha ng isang Libreng Quote

Makikipag-ugnayan sa iyo ang aming kinatawan sa lalong madaling panahon.
Email
Pangalan
Mobile / WhatsApp
Pangalan ng Kumpanya
mensahe
0/1000