सबै श्रेणियाँ
transformer assembly transformer core-0

ट्रान्सफर्मर कम्पोनेन्टहरू

गृहपृष्ठ >  प्रोडक्टहरु >  ट्रान्सफर्मर कम्पोनेन्टहरू

ट्रान्सफर्मर एसेम्बली ट्रान्सफर्मर कोर

  • परिचय
  • सिफारिस उत्पादन

According to the different uses of the iron core, our company can produce various types of iron cores such as laminated iron cores, three-phase three-dimensional wound iron cores, and amorphous alloy iron cores.

Transformers are manufactured based on the principle of electromagnetic induction,and the magnetic circuit is the medium for electrical energy conversion.

The iron core is the main magnetic circuit of the transformer, and its main function is to conduct magnetism. It converts the electrical energy of the primary circuit into magnetic energy, and then converts the magnetic energy into the electrical energy of the secondary circuit.

At the same time, the iron core is also the mechanical skeleton of the transformer. The clamping device of the iron core not only makes the magnetic conductor a complete mechanical structure, but also has insulated coils sleeved on it, supports the leads, and installs almost all the internal components of the transformer.

The iron core has the largest weight among all the components of the transformer. It accounts for about 60% of the total weight in dry-type transformers and about 40% in oil-immersed transformers.

 

विवरण टाइप गर्नुहोस्

 

1.jpg

 

प्रदर्शन प्यारामिटर

 

सं परीक्षण वस्तुहरू मानक आवश्यकताहरू वास्तविक डाटा
1 सीम ≤1.0mm 1.0mm
2 नो-लोड घाटा PO≤553W 540W
3 Window diagonal ≤2.0mm 1.2mm
4 इन्सुलेशन प्रतिरोध Iron core to ground insulation resistance 5MΩ Ω5MΩ
5 स्टेम Verticalltys(2/1000)mm s(2/1000)mm
Curvatures(1.5/1000)mm s(1.5/1000)mm
6 Lamination thickness Main stage:60±1mm 60mm
Total stack thickness: 260±1mm 260mm
7 Window height and width Window height:317±1mm 317mm
Window width:185±1mm 185mm
8 Clamp sizo Strictly implemented in accordance with the technical agreement,non-standardclamps implemented in accordance with the national standard dimensionaltolerance (C-level roughness) पास गरियो
9 Laminated wood:32.5±0.5mmFoot insulation 32.5±0.5mmPressboard:6±0.5mm6±0.5mm 32.5mm
6mm
10 Standard part siz0 Strictly implemented in accordance with the technical agreement,non-standardparts implemented in accordance with the national standard dimensionaltolerance (C-level roughness) पास गरियो
11 समग्र उपस्थिति Strictly implemented in accordance with the technical agreement,non-standard implemented in accordance with the national standard dimensionaltolerance(C-level roughness) पास गरियो