kyn-0

KYN

  • परिचय
  • सिफारिस उत्पादन

Our company can produce this product with a voltage class range of 1-40.5kV and below.The KYN series switchgear is an armored withdrawable AC metal-enclosed switchgear. It is suitable for a three-phase AC 50Hz power system, used for receiving and distributing electrical energy, and implementing control, protection, and monitoring of the circuit.

The main models are KYN28A-12, KYN28A-24, and KYN61-40.5. It can be equipped with various indoor vacuum circuit breakers and can be installed with microcomputer protection as a combined electrical appliance to achieve remote measurement,remote control, remote signaling, and unattended operation. It is mainly used for power transmission of small and medium-sized generators in power plants, power distribution in industrial and mining enterprises, station service transformers in the power system,power distribution in high-rise commercial centers and residential areas, for implementing control, protection, and monitoring.

For the KYN28A-12 and KYN28A-24 series switchgear, the switchgear as a whole is composed of two major parts: the cabinet body and the center-mounted withdrawable components (i.e., the circuit breaker carriages). The cabinet body is divided into four separate compartments. The protection level of the outer shell is IP4X, and the protection level when the doors ofeach compartment and the circuit breaker compartment are open is IP2X.

It has overhead incoming and outgoing line, cable incoming and outgoing line,and other functional schemes. After being arranged and combined, it forms a complete set of power distribution system equipment. This switchgear can be installed,debugged, and maintained from the front. Therefore, it can be installed back-to-back, in double rows, and against the wall, which improves the safety and flexibility of the switchgear and reduces the occupied area.

 

मापदण्डहरू लागू गर्नुहोस्

 

IEC 62271 "उच्च भोल्टेज स्विचगियर र नियन्त्रण उपकरण"

GB/T11022 "उच्च भोल्टेज स्विचगियर र नियन्त्रण उपकरण मानक सामान्य प्राविधिक आवश्यकताहरू"

 

विवरण टाइप गर्नुहोस्

 

1.jpg

 

सामान्य सेवा अवस्था

 

परिवेशको हावाको तापक्रम: -१५℃~+४०℃

उचाइ: १००० मिटर र तल

सापेक्षिक आर्द्रता: दैनिक औसत सापेक्षिक आर्द्रता ९५% भन्दा बढी हुनु हुँदैन, र मासिक औसत सापेक्षिक आर्द्रता ९०% भन्दा बढी हुनु हुँदैन।

भूकम्पको तीव्रता: ८ डिग्रीभन्दा बढी नहुने

आगो, विस्फोटको जोखिम, गम्भीर प्रदूषण, रासायनिक क्षरण र गम्भीर कम्पन नभएका ठाउँहरू

 

प्रदर्शन प्यारामिटर

 

नाम एकाइ तथ्याङ्क
Matched circuit breaker
ZN63A-12(VS1) VD4
रेटेड भोल्टेज KV 12 12
1 मिनेट पावर आवृत्ति भोल्टेज सामना kV 42 42
Rated impulse withstand volage(peak) kV 75 75
रेटेड आवृत्ति Hz 50 50
रेटेड वर्तमान A 630,1250,1600,2000,2500,3150,4000,5000
Rated current of branch busbar A 630,1250,1600,2000,2500,3150,4000,5000
मूल्याङ्कन गरिएको छोटो-समय वर्तमान सामना (भर्चुअल मान) kA 16,20,25,31.5,40,50 16,20,25,31.5,40,50
रेटेड पीक वर्तमानको सामना गर्दछ kA 40,50,63,80,100,125 40,50,63,80,100,125
मूल्याङ्कन गरिएको छोटो सर्किट अवधि S 4
सुरक्षा स्तर The sell is IP4X and it is IP2X when the compartment door andhandcart door is opened
वजन kg 700-1200 700-1200