- மேலோட்டம்
- பரிந்துரைக்கப்பட்ட தயாரிப்புகள்
The structural design of the dry-type transformer with second-level energy efficiency is advanced, and high-temperature insulation materials that are resistant to both sound and visual influence are adopted. It has the characteristics of good no-load energy consumption, safety and reliability, etc., ensuring a stable power output.
It is mainly used for the wiring of electrical circuits, electrical equipment and electromechanical equipment, providing stable power output quality for the power matching of various electrical and mechanical equipment.
It has a high insulation class and stable and reliable performance. In practical applications, it can provide continuous and stable high-quality voltage transformation services.
It has high working efficiency and can provide efficient power output to ensure the safe operation of the power supply.
It has good heat dissipation performance and excellent performance reliability during long-term operation.
தரநிலைகளை அமல்படுத்து
GB 1094-2013 《Power transformer》
GB/T 2900.95 Electrical terms transformers, voltage regulator and reactors
GB/T 10228 Technical parameters and requirements of dry type powertransformers
GB 20052-2020 Power transformer energy efficiency limit value and energy
IEC 60076 《Power transformer》
விளக்கத்தை தட்டச்சு செய்க
இயல்பான சேவை நிலை
1000 மீட்டர் உயரத்திற்குக் கீழே
அதிகபட்ச சுற்றுப்புற வெப்பநிலை +40 டிகிரி செல்சியஸ் ஆகும்.
அதிகபட்ச தினசரி சராசரி வெப்பநிலை +20 டிகிரி செல்சியஸ் ஆகும்.
குறைந்தபட்ச வெளிப்புற வெப்பநிலை -20 டிகிரி செல்சியஸ் ஆகும்.
செயல்திறன் அளவுரு
மதிப்பிடப்பட்ட கொள்ளளவு (kVA) | Electrical steel belt | உருவமற்ற கலவை | Short-circuitimpedence(%) | ||||||
சுமை இல்லாத இழப்பு(W) | சுமை இழப்பு(W) | சுமை இல்லாத இழப்பு(W) | சுமை இழப்பு(W) | ||||||
B (100℃) | F(120℃) | H(145℃) | B(100℃) | F(120℃) | H(145℃) | ||||
30 | 130 | 605 | 640 | 685 | 60 | 605 | 640 | 685 | 4.0 |
50 | 185 | 845 | 900 | 965 | 75 | 845 | 900 | 965 | |
80 | 250 | 1160 | 1240 | 1330 | 100 | 1160 | 1240 | 1330 | |
100 | 270 | 1330 | 1415 | 1520 | 110 | 1330 | 1415 | 1520 | |
125 | 320 | 1565 | 1665 | 1780 | 130 | 1565 | 1665 | 1780 | |
160 | 365 | 1800 | 1915 | 2050 | 145 | 1800 | 1915 | 2050 | |
200 | 420 | 2135 | 2275 | 2440 | 170 | 2135 | 2275 | 2440 | |
250 | 490 | 2330 | 2485 | 2665 | 195 | 2330 | 2485 | 2665 | |
315 | 600 | 2945 | 3125 | 3355 | 235 | 2945 | 3125 | 3355 | |
400 | 665 | 3375 | 3590 | 3850 | 265 | 3375 | 3590 | 3850 | |
500 | 790 | 4130 | 4390 | 4705 | 305 | 4130 | 4390 | 4705 | |
630 | 910 | 4975 | 5290 | 5660 | 360 | 4975 | 5290 | 5660 | |
630 | 885 | 5050 | 5365 | 5760 | 350 | 5050 | 5365 | 5760 | 6.0 |
800 | 1035 | 5895 | 6265 | 6715 | 410 | 5895 | 6265 | 6715 | |
1000 | 1205 | 6885 | 7315 | 7885 | 470 | 6885 | 7315 | 7885 | |
1250 | 1420 | 8190 | 8720 | 9335 | 550 | 8190 | 8720 | 9335 | |
1600 | 1665 | 9945 | 10555 | 11320 | 645 | 9945 | 10555 | 11320 | |
2000 | 2075 | 12240 | 13005 | 14005 | 850 | 12240 | 13005 | 14005 | |
2500 | 2450 | 14535 | 15445 | 16605 | 1020 | 14535 | 15445 | 16605 |