Alle categorieën
scb 10  3031500kva three phase dry type transformer-0

Droge transformatoren

Home >  Onze Producten >  transformers >  Droge transformatoren

SCB (10) -30~31500kVA Drie-fase droge transformator

  • Overzicht
  • Aanbevolen producten

This series of dry-type transformers with fillers and thin insulation. Because the coils are encapsulated by epoxy resin,they are flame-retardant, fireproof, explosion-proof,maintenance-free, pollution-free and small in size, and can be directly installed in the load center.

Meanwhile,the scientific and reasonable design and pouring process make the product have a smaller partial discharge amount, lower noise and stronger heat dissipation capacity.Under the condition of forced air cooling, it can operate continuously at 140% of the rated load for a long time, and is equipped with an intelligent temperature controller for centralized monitoring and control.

The foil-type coil can solve problems such as high short-circuit stress of products wound with low-voltage and large-current coils, unbalanced ampere-turns, poor heat dissipation effect, large winding helix angle, and unstable quality of manual welding.

At the same time, the winding ends of our company adopt resin sealing, curing, moisture-proof and anti-fouling measures, and the copper busbars are automatically welded by argon arc welding.

 

Handhaaf normen

 

GB 1094-2013 《Vermogenstransformator》

GB/T 2900.95 Elektrische termen transformatoren, spanningsregelaars en reactoren

GB/T 10228 Technische parameters en eisen voor droge vermogenstransformatoren

GB 20052-2020 Energie-efficiëntiegrenswaarde en energie-efficiëntie van vermogenstransformatoren

IEC 60076 《Vermogenstransformator》

 

Typ een beschrijving

 

1.jpg

 

Normale serviceconditie

 

Onder een hoogte van 1000 meter

De hoogste omgevingstemperatuur is +40 graden Celsius

De hoogste dagelijkse gemiddelde temperatuur is +20 graden Celsius

De laagste buitentemperatuur is -20 graden Celsius

 

 

Prestatie parameter

 

Nominale capaciteit (kVA) Spanningsgroep Impedantiespanning (%) SC(B)10 Soundlevel Afmetingen (mm) Gewicht (kg)
HV(kV) Tikbereik LV(kV) Nullastverlies (W) Load loss 120℃ (W) No-load curren(%) (DB) L W H
30 101110.56.66.36 ±2x2.5%±5% 0.4 4 190 710 2.0 44 620 400 600 220
50 270 1000 2.0 44 650 400 740 320
80 370 1380 1.5 45 750 500 770 460
100 400 1570 1.5 45 800 500 830 580
125 470 1850 1.3 46 950 880 1090 750
160 540 2130 1.3 46 950 880 1090 780
200 620 2530 1.1 47 1050 900 1200 850
250315 720 2760 1.1 48 1050 900 1200 1030
400 880980 34703990 1.01.0 4849 10801110 900950 12501270 10601400
500 1160 4880 1.0 49 1130 950 1380 1550
630 1340 5880 0.85 49 1200 950 1450 1820
630 6 1300 5960 0.85 50 1320 950 1375 1850
800 1520 6960 0.85 51 1310 1000 1315 2150
1000 1770 8130 0.85 52 1400 1070 1520 2550
1250 2090 9690 0.85 53 1440 1150 1570 3020
1600 2450 11730 0.85 54 1650 1200 1795 4500
2000 3050 14450 0.7 55 1800 1260 1870 5300
2500 3600 17170 0.7 56 1950 1260 2035 6200

Ontvang een gratis offerte

Onze vertegenwoordiger zal spoedig contact met u opnemen.
E-mail
Naam
Bedrijfsnaam
Bericht
0/1000
onderzoek

Ontvang een gratis offerte

Onze vertegenwoordiger zal spoedig contact met u opnemen.
E-mail
Naam
Mobiel / WhatsApp
Bedrijfsnaam
Bericht
0/1000