ທຸກຫມວດຫມູ່
transformer assembly transformer core-0

Transformer assembly ຫຼັກ Transformer

  • ພາບລວມ
  • ຜະລິດຕະພັນທີ່ແນະນໍາ

According to the different uses of the iron core, our company can produce various types of iron cores such as laminated iron cores, three-phase three-dimensional wound iron cores, and amorphous alloy iron cores.

Transformers are manufactured based on the principle of electromagnetic induction,and the magnetic circuit is the medium for electrical energy conversion.

The iron core is the main magnetic circuit of the transformer, and its main function is to conduct magnetism. It converts the electrical energy of the primary circuit into magnetic energy, and then converts the magnetic energy into the electrical energy of the secondary circuit.

At the same time, the iron core is also the mechanical skeleton of the transformer. The clamping device of the iron core not only makes the magnetic conductor a complete mechanical structure, but also has insulated coils sleeved on it, supports the leads, and installs almost all the internal components of the transformer.

The iron core has the largest weight among all the components of the transformer. It accounts for about 60% of the total weight in dry-type transformers and about 40% in oil-immersed transformers.

 

ພິມຄໍາອະທິບາຍ

 

1.jpg

 

ຕົວກໍານົດການປະຕິບັດງານ

 

ສະບັບເລກທີ ລາຍການທົດສອບ ຄວາມຕ້ອງການມາດຕະຖານ ຂໍ້ມູນຕົວຈິງ
1 ຊີມ 1.0mm 1.0mm
2 ການສູນເສຍທີ່ບໍ່ມີການໂຫຼດ PO≤553W 540W
3 Window diagonal 2.0mm 1.2mm
4 ການຕໍ່ຕ້ານ insulation Iron core to ground insulation resistance 5MΩ ≥5MΩ
5 ຕົ້ນກໍາເນີດ Verticalltys(2/1000)mm s(2/1000)mm
Curvatures(1.5/1000)mm s(1.5/1000)mm
6 Lamination thickness Main stage:60±1mm 60mm
Total stack thickness: 260±1mm 260mm
7 Window height and width Window height:317±1mm 317mm
Window width:185±1mm 185mm
8 Clamp sizo Strictly implemented in accordance with the technical agreement,non-standardclamps implemented in accordance with the national standard dimensionaltolerance (C-level roughness) ຜ່ານໄປ
9 Laminated wood:32.5±0.5mmFoot insulation 32.5±0.5mmPressboard:6±0.5mm6±0.5mm 32.5mm
6mm
10 Standard part siz0 Strictly implemented in accordance with the technical agreement,non-standardparts implemented in accordance with the national standard dimensionaltolerance (C-level roughness) ຜ່ານໄປ
11 ຮູບລັກສະນະໂດຍລວມ Strictly implemented in accordance with the technical agreement,non-standard implemented in accordance with the national standard dimensionaltolerance(C-level roughness) ຜ່ານໄປ

Get Free Quote

ຕົວແທນຂອງພວກເຮົາຈະຕິດຕໍ່ຫາທ່ານໃນໄວໆນີ້.
Email
ຊື່
ຊື່​ບໍ​ລິ​ສັດ
ຂໍ້ຄວາມ
0/1000
ສອບຖາມ

Get Free Quote

ຕົວແທນຂອງພວກເຮົາຈະຕິດຕໍ່ຫາທ່ານໃນໄວໆນີ້.
Email
ຊື່
ມືຖື/WhatsApp
ຊື່​ບໍ​ລິ​ສັດ
ຂໍ້ຄວາມ
0/1000