Όλες οι κατηγορίες
lmzj1 066-0

LMZJ1-0.66

  • Επισκόπηση
  • Προτεινόμενα Προϊόντα

The LMZJ1-0.66 type current transformer is suitable for indoor use.

It is applicable in an alternating current circuit with a maximum equipment voltage of 0.72KV and below, a load power factor of 0.8, and a rated frequency of 50Hz for measuring current.

It is used for the measurement or metering of electrical energy.

The product is of the casting type and is installed in a way of fixing it with the busbar.

 

Επιβολή προτύπων

 

GB/T 20840《Transformer》

IEC 61869《Μετασχηματιστές οργάνων》

 

Κανονική κατάσταση σέρβις

 

The altitude does not exceed 1000m.

The ambient temperature for the use of the current transformer is: indoors -5℃ to 40℃.

The current transformer is for indoor use, and the other considered operating conditions are as follows:

a) The influence of solar radiation can be ignored.

b) The ambient air has no obvious pollution from dust, smoke, corrosive gases, vapors or salts.

c) The humidity conditions are as follows:

1) The average value of the relative humidity measured within 24 hours does not exceed 95%.

2) The average value of the water vapor pressure within 24 hours does not exceed 2.2kPa.

3) The average value of the relative humidity within one month does not exceed 90%.

4)The average value of the water vapor pressure within one month does not exceed 1.8kPa.

 

Παράμετρος απόδοσης

 

Αριθμός μοντέλου Current ratio A Rated output VA Number of turns through the heart
0.5rank 0.5S rank Κατάταξη 0.2 0.2S rank
30 μου 2000/5 2.5 2.5 2.5 2.5 1
2050/5 5 5 5 5 1
200/5 5 5 5 5 1
250/5 5 5 5 5 1
300/5 5 5 5 5 1
2050/1 2.5 2.5 2.5 2.5 1
200/1 5 5 5 5 1
250/1 5 5 5 5 1
300/1 5 5 5 5 1
40 μου 2050/5 2.5 2.5 2.5 1
200/5 5 5 5 5 1
250/5 5 5 5 5 1
300/5 5 5 5 5 1
400/5 5 5 5 5 1
2050/1 2.5 2.5 2.5 1
200/1 5 5 5 5 1
250/1 5 5 5 5 1
300/1 5 5 5 5 1
400/1 5 5 5 5 1
60 μου 400/5 5 5 5 5 1
500/5 5 5 5 5 1
600/5 5 5 5 5 1
400/1 5 5 5 5 1
500/1 5 5 5 5 1
600/1 5 5 5 5 1
80 μου 800/5 10 10 10 5 1
1000/5 10 10 10 5 1
1200/5 10 10 10 5 1
1500/5 10 10 10 5 1
600/1 10 5 5 5 1
750/1 10 10 10 5 1
800/1 10 10 10 5 1
1000/1 10 10 10 5 1
1200/1 10 10 10 5 1
1500/1 10 10 10 5 1
100 μου 1000/5 10 10 10 5 1
1200/5 10 10 10 5 1
1500/5 10 10 10 5 1
2000/5 20 20 20 10 1
750/1 10 10 10 5 1
800/1 10 10 10 5 1
1000/1 10 10 10 5 1
1200/1 10 10 10 5 1
1500/1 10 10 10 5 1
2000/1 20 20 20 10 1

Πάρτε ένα δωρεάν παράθεση

Ο εκπρόσωπος μας θα επικοινωνήσει μαζί σας σύντομα.
Email
Όνομα
Επωνυμία Εταιρίας
Το μήνυμά σας
0/1000
έρευνα

Πάρτε ένα δωρεάν παράθεση

Ο εκπρόσωπος μας θα επικοινωνήσει μαζί σας σύντομα.
Email
Όνομα
Κινητό / WhatsApp
Επωνυμία Εταιρίας
Το μήνυμά σας
0/1000