SCBH (15) -30~31500kVA Three-phase dry type transformer

  • Overview
  • Recommended Products

Our company can produce various types of this product with a voltage class of 40.5kV and below.

This product has the advantages of low no-load loss, being oil-free, flame-retardant and self-extinguishing, moistureresistant, crack-resistant, and maintenance-free.

Any place where ordinary dry-type transformers are currently used can be replaced by amorphous alloy dry-type transformers.

It can be used in high-rise buildings, commercial centers, airports, oil platforms, subways,tunnels, airports, railway stations, industrial and mining enterprises, and power plants.

It is especially suitable for installation and use in places with high fire protection requirements such as flammable and explosive areas.

 

Enforce standars

 

GB 1094-2013 《Power transformer》

GB/T 2900.95 Electrical terms transformers, voltage regulator and reactors

GB/T 10228 Technical parameters and requirements of dry type powertransformers

GB 20052-2020 Power transformer energy efficiency limit value and energy

IEC 60076 《Power transformer》

 

Type description

 

1.jpg

 

Normal service condition

 

Below an altitude of 1000 meters

The highest ambient temperature is +40 degrees Celsius

The highest daily average temperature is +20 degrees Celsius

The lowest outdoor temperature is -20 degrees Celsius

 

Performance parameter

 

Voltage group Vector Loss(W) No-load current (%) Impedance voltage(%) Weight(Kg) Boundarydimension(LxWxH,mm) Gauge
HV(kV) LV(kV) group No-load loss(W) Load loss75℃ Longitudinal/transverse (mm)
1110.5106.36 0.4 Dyn11 130 1570 12 4 890 950x600x960 550x550
170 2130 1.1 1170 1220x600x1060 550x550
200 2530 1.0 1400 1270x710x1160 660x660
230 2760 1.0 1560 1350x760x1240 660x660
280 3470 0.9 1770 1370x870x1360 820x820
310 3990 0.8 2180 1460x870x1360 820x820
360 4880 0.8 2440 1490x870x1430 820x820
420 5880 0.7 2850 1760x1120x1490 1070x1070
410 5960 0.7 6 3015 1710x970x1450 1070x1070
480 6960 0.7 3430 1850x1120x1600 1070x1070
550 8130 0.6 4050 1900x1120x1170 1070x1070
650 9690 0.6 4690 2030x1120x1880 1070x1070
760 11730 0.6 5610 2120x1120x1970 1070x1070
1000 14450 0.5 5820 2120x1120x1990 1070x1070
1200 17170 0.5 6730 2190x1120x2110 1070x1070