S-30~31500kVA-NX2 Three-phase oil immersed transformer

In response to the national strategic goal of energy conservation and emission reduction, and in combination with the characteristics of our own products, our company, in accordance with the requirements of the energy efficiency grades of energy-saving products specified in theGB20025-2020standard, through continuous research, development and improvement, has designed and produced transformer products of different energy efficiency grades that meet the requirements of the national standard.

  • Overview
  • Recommended Products

Through the research and application of new materials and new processes, as well as continuous independent innovation, and through the optimized design and continuous improvement of the iron core and windings, the goal of reducing losses and noise has been achieved, meeting the requirements of the national standard GB20025-2020.

Moreover, the noise level has decreased by 20% compared with the current national standard JB/T10088-2016,and the product performance has reached the domestic advanced level.

Compared with products of energy efficiency grade 1I, products of energy efficiency grade I have lower losses.

 

Enforce standars

 

GB 1094-2013 《Power Transformer 》

GB 1094-2013 《Power transformer 》

GBT6451-2015 《Oil immersed power transformer technicalparameters and requirements 》

GBT6451-2015 《Oil immersed power transformer technical parameters and requirements 》

IEC 60076 《Power transformer 》

 

Type description

 

1.jpg

 

Performance parameter

 

Rated capacity(kVA) Electrical steel strip Amorphous alloy
No-load loss(W) Load loss(W) No-load loss(W) Load loss(W)
Dym11/Yan11 Vyn0 Dyn11/Yzn11 Yyno
30 70 505 480 33 535 510
50 90 730 695 43 780 745
63 100 870 830 50 930 890
80 115 1050 1000 60 1120 1070
100 135 1265 1200 75 1350 1285
125 150 1510 1440 85 1615 1540
160 180 1850 1760 100 1975 1880
200 215 2185 2080 120 2330 2225
250 260 2560 2440 140 2735 2610
315 305 3065 2920 170 3275 3120
400 370 3615 3440 200 3865 3675
500 430 4330 4120 240 4625 4400
630 510 4960 320 5300
800 630 6000 380 6415
1000 745 8240 450 8800
1250 870 9600 530 10260
1600 1050 11600 630 12400
2000 1225 14640 710 14800
2500 1440 14840 860 16300