S13 Three Phase Oil Immersed Transformer(30kVA~31500kVA)

  • Overview
  • Recommended Products

This series of oil-immersed transformers breaks through the traditional planar structure and adopts a threephase symmetrical three-dimensional structure.

The magnetic circuits of the three-phase iron cores ofthe product are completely symmetrical, the magnetic resistance is greatly reduced, and the exciting current and no-load loss are significantly decreased.

It is an energy-efficient and energy-saving transformer that uses traditional materials but has lower operating noise and a more compact structure.

It has outstanding performance in energy conservation and consumption reduction, as well as material saving and environmental protection.

 

Enforce standars

 

GB 1094-2013 《Power Transformer 》

GB 1094-2013 《Power transformer 》

GBT6451-2015 《Oil immersed power transformer technicalparameters and requirements 》

GBT6451-2015 《Oil immersed power transformer technical parameters and requirements 》

IEC 60076 《Power transformer 》

 

Type description

 

微信截图_20250319154339.jpg

 

Normal service condition

 

Below an altitude of 1000 meters

The highest ambient temperature is +40 degrees Celsius

The highest daily average temperature is +20 degrees Celsius

The lowest outdoor temperature is -25 degrees Celsius

 

 

Performance parameter

 

Ratedcapacity(kVA) Voltage group Vector group Loss(W) No-loadcurrent(%) Impedancevoltage(%) Boundarydimension(LxWxH,mm) Weight(kg)
HV(kV) LV(KV) No-load loss (W) Load loss(W)
30 1110.5106 0.4 Dyn11orYynO 80 630/600 0.3 4 800x620x1100 300
50 100 910/870 0.24 840x640x1150 380
80 130 1090/1040 0.22 980x670x1210 480
100 150 1310/1250 0.21 1040x700x1230 540
125 170 1580/1500 0.20 910x800x1260 590
160 200 1890/1800 0.19 1110x970x1290 720
200 240 2310/2200 0.18 1180x1020x1310 860
250 290 2730/2600 0.17 1190x1030x1300 970
315 340 3200/3050 0.16 1290x1120x1360 1170
400 410 3830/3650 0.16 1280x1110x1410 1320
500 480 4520/4300 0.16 1400x1210x1420 1490
630 570 6200 0.15 4.5 1440x1250x1490 1910
800 700 7500 0.15 1540x1340x1520 2160
1600x1420x1630 2550
1000 830 10300 0.14
1250 970 12000 0.13 1680x1460x1730 3160
1600 1170 14500 0.12 1780x1540x1810 3850