All Categories
mccb series low voltage circuit breaker-0

Low Voltage Circuit Breakers

Home >  Products >  Circuit Breakers >  Low Voltage Circuit Breakers

MCCB Series Low-voltage circuit breaker

  • Overview
  • Recommended Products

Plastic case type low-voltage circuit breakers are suitable for alternating current with a frequency of 50Hz or 60Hz.

Our company can produce this kind of product with a rated voltage of less than 1kV and a rated current of 800A and below.

It integrates comprehensive protection, high-precision measurement, control, and communication functions, and has high sensitivity.

This product is mainly used in low-current low-voltage switchgear, distribution boxes,and other low-voltage power distribution line networks, as well as in new energy power generation.

 

Enforce standars

 

GB/T 14048 Low voltage switchgear and control equipment

IEC 60947-2 Low voltage switchgear and control equipment

 

Type description

 

1.jpg

 

Normal service condition

 

Temperature: -25 degrees Celsius to +70 degrees Celsius

Altitude: less than or equal to 2500 meters

Pollution/Protection Level:Level 3/IP20

 

Performance parameter

 

Modelnumber Bracketratingcurrent(A) Ratedcurrent(A) Rated operatingvoltageUe(V) Rated in-sulationvoltageUi(V) Flutterimpulsewith-standvoltageUimp(kV) Ratedlimitshort-cir-cuitbreakingcapacity(kA) Rated op-eratingshort-cir-cuitbreakingcapacity(kA)400V/690V Main-tainablemachinelife(second) ElectricallifeAC400V(times) Numberof poles Arcdistance(mm)
EWS-63S 63 10,16,20,25,32.4050.63 400 500 8 25* 12.5° 20000 3000 3 ≤50
EWS-63H 63 50*50* 25* 20000 3000 3
25* 20000 3000 4
EWS-125S 125 16,20,25,32,40,50.63,80,100,125 400/690 800 8 35/8 17.5/4 20000 3000 2.3 ≤50
35/8 17.5/4 20000 3000 4
EWS-125H 125 50/10 25/5 20000 3000 2,3,4
EWS-125R 125 85/20 425/10 20000 3000 3
EWS-250S 250 125,160,180.200,225,250 400/690 800 8 35/8 18/4 20000 3000 2.3 ≤50
35/8 18/4 20000 3000 4
EWS-250H 250 50/10 25/5 20000 3000 2,3,4
EWS-250R 250 85/20 42.5/10 20000 3000 3
EWS-400S 400 250,315,350,400 400/690 800 8 50/10 25/5 10000 2000 3 s100
50/10 25/5 10000 2000 4
EWS-400H 400 65/2065/20 325/10 10000 2000 3
32.5/10 10000 2000 4
EWS-400R 400 100/20 50/10 10000 2000 3
EWS-630S 630 400,500,630 400/690 800 8 50/10 25/5 10000 2000 3
50/10 25/5 10000 2000 4 ≤100
EWS-630H 630 65/10 32.5/5 10000 2000 3,4
EWS-630R 630 100/20 50/10 10000 2000 3
EWS-800S 800 630,700,800 400/690 800 8 50/10 25/5 10000 2000 3
50/10 25/5 10000 2000 4 ≤100
EWS-800H 800 75/3075/30 37.5/1537.5/15 10000 2000 3
10000 2000 4
EWS-800R 800 100/30 50/15 10000 2000 3
EWS-1250S 1250 800,1000,1250 400/690 800 8 65/20 32.5/10 5000 800 3 ≤100
EWS-1250H 1250 85/25 42.5/12.5 5000 800 3 s100

3.jpg

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
inquiry

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile/WhatsApp
Company Name
Message
0/1000