All Categories
scb 11 3031500kva tria tempus arida genus TRANSFIGURATOR-0

Arida-genus Transformers

domum >  Products >  Transformers >  Arida-genus Transformers

SCB (11) -30~ 31500kVA Tres-phase sicco genus transformer

  • Overview
  • Suspendisse Products

Compared with the SCB10 product, the no-load loss is reduced by 12%.

The noise level is reduced, which greatly improves the economic benefits.

It has high mechanical strength, good short-circuit resistance, flame retardancy, explosion prevention, and no pollution. It can be directly installed on the load.

It is maintenance-free, has good moisture resistance, can operate under 100% humidity,does not require preheating treatment before commissioning, and does not require dehumidification treatment during intermittent operation.

It has a small external dimension, light weight, and low partial discharge.

It has a high insulation level and good resistance to lightning impulse.

It has strong heat dissipation ability and can operate at 150% of the rated load under the condition of cold air.

 

Exeat signa

 

GB 1094-2013 Potestas transformer》

GB/T 2900.95 Termini electricae transformatores, voltage moderatoris et reactors

GB/T 10228 Parametri Technical et requisita aridi generis powertransformers

GB 20052-2020 Virtus transformer energiae efficientiam limitis valoris et industriae

IEC (DC)LXXVI Power transformer》

 

Typus descriptio

 

1.jpg

 

Normalis servitium conditio

 

Infra altitudinem 1000 metrorum

Summus temperatus ambiens +40 gradus Celsius est

Summa cotidie mediocris temperatus est +20 gradus Celsius

Infimus temperatus velit -20 graduum Celsius

 

euismod parametri

 

Ratedcapacity(kVA) Circulus intentionis SC(B)11 Ratio (mm) Pondus (kg)
HV(kV) Taprange LV(kV) Impedancevoltage(%) No-loadloss(W) Load loss120℃(W) Nullus loadcurrent(%) Soundlevel(dB) L W H
30 101110.56.66.36 ±2x2.5%±5% 04 4 170 710 2.0 44 620 400 600 220
50 250 1000 2.0 44 650 400 740 320
80 330 1380 1.5 45 750 500 770 460
100 360 1570 1.5 45 800 500 830 580
125 420 1850 1.3 46 950 880 1090 750
160 490 2130 1.3 46 950 880 1090 780
200 560 2530 1.1 47 1050 900 1200 850
250 650 2760 1.1 48 1050 900 1200 1030
315 790 3470 1.0 48 1080 900 1250 1060
400 880 3990 1.0 49 1110 950 1270 1400
500 1040 4880 1.0 49 1130 950 1380 1550
630 1210 5880 0.85 49 1200 950 1450 1820
630 6 1170 5960 0.85 50 1320 950 1375 1850
800 1370 6960 0.85 51 1310 1000 1315 2150
1000 1590 8130 0.85 52 1400 1070 1520 2550
1250 1880 9690 0.85 53 1440 1150 1570 3020
1600 2210 11730 0.85 54 1650 1200 1795 4500
2000 2750 14450 0.7 55 1800 1260 1870 5300
2500 3240 17170 0.7 56 1950 1260 2035 6200

A Free Quote

Procurator noster mox te contact.
Email
nomine
nomen corporationis
Nuntius
0/1000
inquisitionis

A Free Quote

Procurator noster mox te contact.
Email
nomine
Mobile / whatsapp
nomen corporationis
Nuntius
0/1000