D-30~6300kVA Unio-phase olei immersor
In the distribution network with dispersed power supply, single-phase transformers have great advantages as distribution transformers.
It can reduce the length of low-voltage distribution lines, reduce line losses, and improve the power supply quality.
- Overview
- Suspendisse Products
With the design of a high-efficiency and energy-saving wound core structure, the characteristic of this transformer is that it adopts the overhead suspension installation method. It has a small volume and requires a small capital construction investment. It can reduce the low-voltage power supply radius and can reduce the low-voltage line losses by more than 60%.
The transformer adopts a fully sealed structure, has a strong overload capacity, high reliability for continuous operation, simple maintenance, and a long service life.
It is suitable for rural power grids, remote areas, scattered villages, agricultural production, lighting, and power consumption. It can also be used for the energy-saving renovation of overhead distribution lines in railway and urban power grids.
It has the characteristics of small volume, convenient installation, simple maintenance,low noise, low line loss, high efficiency and energy saving, reliable operation, and strong overload capacity.
Peculiaritas
Small in size, easy to install and simple to maintain.
Low noise, low line loss, highly efficient and energy-saving.
Reliable in operation and with strong overload capacity.
Exeat signa
JBT 10317-2014: Technical parameters and requirements of singlephase oil immersed distribution transformers
Typus descriptio
euismod parametri
Facultatem rated (kVA) | Coniunctio intentione percussoque range | Join group label | Nullus onus damnum (W) | Load damnum (W) | No-load current(%) | Short-circuit impedance(%) | ||
High tension(kV) | High pressure tap range(%) | Low pressure(kV) | ||||||
5 | 66.31010.511 | ±2x2.5±5 | 0.220.230.24 | lioli6 | 40 | 215 | 3.2 | 3.5 |
10 | 45 | 235 | 2.8 | |||||
15 | 53 | 315 | 2.8 | |||||
20 | 62 | 405 | 2.8 | |||||
25 | 70 | 480 | 2.8 | |||||
30 | 80 | 560 | 2.8 | |||||
50 | 120 | 855 | 23 | |||||
63 | 135 | 1020 | 21 | |||||
80 | 160 | 1260 | 2.0 | |||||
100 | 190 | 1485 | 1.9 | |||||
125 | 220 | 1755 | 1.8 | |||||
160 | 260 | 2050 | 1.6 |
Ratedcapacity(kVA) | Voltagegroup | Vector | IMMINENTIA | Damnum (W) | Nullus loadcurrent(%) | Pondus (kg) | Terminatio (LxWxH, mm) | Gaugevertical/Horizonta | ||||
HV(kV) | LV(kV) | Group | voltage(%) | No-loadloss | Loadloss | Corpus pondus | Oilweight | Grossweight | ||||
5 | 1110.5106.36 | 0.220.24 | Li0Li6 | 3.5 | 35 | 145 | 4 | 50 | 40 | 130 | * * 530 450 850 | 400/250 |
10 | 35 | 260 | 3.5 | 65 | 40 | 150 | III V ^ | 400/300 | ||||
16 | 65 | 365 | 3.2 | 80 | 40 | 180 | * * 600 450 920 | 400/300 | ||||
20 | 80 | 430 | 3.0 | 100 | 50 | 205 | * * 620 450 940 | 400/300 | ||||
30 | 100 | 625 | 2.5 | 115 | 50 | 225 | * * 700 450 980 | 400/300 | ||||
40 | 125 | 775 | 2.5 | 150 | 55 | 270 | * * 700 480 1040 | 400/300 | ||||
50 | 150 | 950 | 2.3 | 175 | 70 | 310 | * * 850 510 1100 | 400/300 | ||||
63 | 180 | 1135 | 2.1 | 190 | 80 | 340 | * * 660 520 1100 | 400/300 | ||||
80 | 200 | 1400 | 2.0 | 240 | 100 | 420 | * * 770 530 1120 | 400/300 | ||||
100 | 240 | 1650 | 1.9 | 295 | 100 | 490 | 840*6001150 | 400/300 | ||||
285 | 1950 | 1.8 | 370 | 110 | 560 | * * 890 740 1160 | 500/400 | |||||
125 | ||||||||||||
160 | 365 | 2365 | 1.7 | 430 | 130 | 650 | * * 950 790 1170 | 500/400 |