All Categories
ewr-0

Medium Voltage Switchgear

Home >  Products >  Switchgear >  Medium Voltage Switchgear

  • Overview
  • Recommended Products

Our company can produce this product with a voltage class range of 1-40.5kV and below.

The fully enclosed and fully insulated gas-filled ring main unit is a metal common box type enclosed switchgear insulated by SF6 gas. This equipment can be composed of modules such as the load switch unit, the combined electrical appliance unit of load switch and fuse, the vacuum circuit breaker unit, and the busbar incoming line unit. By adopting a series of excellent technologies and materials, it has excellent electrical and mechanical properties, is less affected by the environment and climate, is compact in size, easy to install,convenient to operate, maintenance-free, and has a flexible combination mode.

Theclear and intuitive design ensures simple and direct operation. It has a large feeder connection capacity and is suitable for a variety of wiring systems. Through us, we can provide users with an integrated three-position load switch circuit breaker.

Using a load switch instead of a disconnector is safer and more reliable. The fully enclosed design on the primary side provides protection against accidental contact, and the mechanical interlock live-line indicator that meets the "five-prevention" requirements can provide live-line indication for the incoming and outgoing lines.

Reliable operation: With a fully enclosed design, all switches and live busbar conductors are sealed in an air box welded by 3mm stainless steel plates; equipped with silicone rubber cable plugs to achieve full insulation and full sealing of the cable ends,thus not being affected by external environmental factors such as dust, humidity,and small animals. The spring energy storage operating mechanism can be operated manually or electrically. The simulated wiring diagram on the operation panel provides switch position indication. The cabinet body is made of galvanized steel plates and electrostatically sprayed on the surface to enhance corrosion resistance.

The pressure gauge monitors the safe pressure range of SF6 gas in the box body. The main models of this product are EWR-12, EWR-24, and EWR-40.5.

This product has the characteristics of being maintenance-free, highly reliable, with a service life of up to 20 years, having multiple incoming line methods, being able to achieve left, right, upper or front incoming lines, and multiple combination methods.

Arbitrary combination can be achieved between each unit. Using insulated busbars, it can achieve front-to-back or left-to-right cabinet combination. The design scheme is flexible,the feeder outlet capacity is large, the floor space is small, and it is suitable for a variety of application requirements. It is mainly applicable to the power distribution networks of compact secondary substations, small industrial and mining enterprises,wind power plants, hotels, shopping malls, office buildings, commercial centers, etc.

 

Enforce standards

 

GB 1984-2003 High voltage AC circuit breaker

GB 1985-2005 High voltage AC isolation switch and ground switch

GB 3804-2004 3.6kV ~ 40.5kV high voltage AC load switch

IEC60265 High-voltage switches

GB 16926-2009 AC high voltage load switch fuse combination

IEC420 High-voltage alternatingcurrent switch-fusecombinations

GB 3906-2006 3.6kV ~ 40.5kV AC metal enclosed switchgear and control equipment

IEC62271 High-voltage switchgear and controlgear

GB/T11022-2011 Common technical requirements for high voltage switchgear and control equipment standards

IEC60694 Common specifications for high-voltageswitchgear and controlgear standards

GB/T11023 High pressure switchgear - sulfur hexafluoride gas seal test method

GB 4208-2008 Enclosure protection class

IEC60529 Degrees of protection provided by enclosures(IP Code)

DL/T404 3.6kV ~ 40.5kV AC metal enclosed switchgear and control equipment

DL/T 728-2000 Technical Guide for ordering gas insulated metal enclosed switchgear

 

Type description

 

1.jpg

Get a Free Quote

Our representative will contact you soon.
Email
0/100
Name
0/100
Company Name
0/200
Message
0/1000
inquiry

Get a Free Quote

Our representative will contact you soon.
Email
0/100
Name
0/100
Mobile/WhatsApp
0/100
Company Name
0/200
Message
0/1000