All Categories
acb series low voltage circuit breaker-0

Low Voltage Circuit Breakers

Home >  Products >  Circuit Breakers >  Low Voltage Circuit Breakers

ACB Series Low-voltage circuit breaker

  • Overview
  • Recommended Products

In the distribution network of 6300A and below, it is used to distribute electrical energy and protect the lines and power supply equipment from hazards such as overload, undervoltage, short circuit and single-phase grounding faults.

This circuit breaker has intelligent protection functions, with precise selective protection, which can improve the reliability of power supply and avoid unnecessary power outages.

It complies with the standards: GB/T 14048.2, IEC/EN 60947-2.In the distribution network of 6300A and below, it is used to distribute electrical energy and protect the lines and power supply equipment from hazards such as overload, undervoltage, short circuit and single-phase grounding faults.

This circuit breaker has intelligent protection functions, with precise selective protection,which can improve the reliability of power supply and avoid unnecessary power outages.

 

Enforce standars

 

GB/T 14048 Low voltage switchgear and control equipment

IEC 60947-2 Low voltage switchgear and control equipment

 

Type description

 

1.jpg

 

Normal service condition

 

Temperature: -25℃to +70℃

Altitude: less than or equal to 2500 meters

Pollution/Protection level: Level 3/IP20

 

Performance parameter

 

Model number EWK-1000
Rated limit short-circuit break-ing capacity lcu(kA) 42 400V 25 690
Rated operating short-circuit break-ing capacity lcs(kA) 30 400V 20 690
Rated short-time withstand currentlcw(kA) 30 400V 20 690
Rated current In(A) 200 400 630 8001000
Number of poles 3 level, 4 level
Rated voltage Ue(V) AC400,AC690
Rated insulation voltage Ui(V) 1000
Rated impulse withstandvoltage Uimp(kV) 12
Short-circuit making capacity lcm=88.2kA AC400V lcm=52.5kA AC690V
N maximum continuous current In(A) 100%In
Total breaking time (no additionaldelay)(ms) ≤28
Closing time (ms) ≤50
Intelligentcontroller Type M/Type H
Operatingperformance(sub) Electrical life AC400V:6500,AC690V:3000
Mechanical life maintenance-free 15000
Be maintained 30000
Connection mode Horizontal
Net weight(kg) Drawer typetriple/quadrupole 38/55
Fixed tripole/quad-rupole 22/26.5
Gross weight(kg) Drawer typetripl /quadrupole 46/63
Fixed tripole/quad-rupole 30/34.5
Arc distance (mm) 0

 

Model number EWK-2000
Rated limit short-circuit break-ing capacity leu(kA) 80 400V 50 690V
Rated operating short-circuit break-ing capacity lcs(kA) 80 400V 40 690V
Rated short-time withstand currentlcw(kA) 50 400V 40 690V
Rated current In(A) 630 800 1000 1250 1600 2000
Number of poles 3.4
Rated voltage Ue(V) AC400,AC690/500
Rated insulation voltage Ui(V) 1000
Rated impulse withstandvoltage Uimp(kV) 12
Short-circuit making capacity Icm=176kAAC400V Icm=105kA AC690V
N maximum continuous current In(A) 100%In
Total breaking time (no additionaldelay)(ms) ≤28
Closing time (ms) ≤50
Intelligentcontroller Type M/Type H . .
Operatingperformance(sub) Electrical life AC400V:8000,AC690V:3000
Mechanical life maintenance-free 15000
Be maintained 30000
Connection mode Horizontal and vertical
Net weight(kg) Drawer typetriple/quadrupole 67.5/80 70/84 70/84 70/84 70/84 79/90.5
Fixed tripole/quad-rupole 42/52 44/52 44/52 44/52 44/52 45/54
Gross weight(kg) Drawer typetriple/quadrupole 79.5/94 82/98 82/98 82/98 82/98 91/104.5
Fixed tripole/quad- 54/66 56/66 56/66 56/66 56/66 57/68
Arc distance (mm) 0

 

Model number EWK-3200 EWK-4000
Rated limit short-circuit break-ing capacity lcu(kA) 100 400V 65 690V
Rated operating short-circuit break-ing capacity lcs(kA) 80 400V 65 690V
Rated short-time withstand currentlcw(kA) 80 400V 50 690V
Rated current In(A) 2000 2500 3200 4000
Number of poles 3,4 3,4 3,4 3,4
Rated voltage Ue(V) AC400,AC690/500 AC400
Rated insulation voltage Ui(V) 1000
Rated impulse withstandvoltage Uimp(kV) 12
Short-circuit making capacity Icm=220kA AC400V cm=143kA AC690V
N maximum continuous current In(A) 100%In 50%In
Total breaking time (no additionaldelay)(ms) ≤28
Closing time (ms) ≤50
Intelligentcontroller Type M/Type H ` ` `
Operatingperformance(sub) Electrical life AC400V:7000,AC690V:2000 AC400V:1500,AC690V:1000
Mechanical life maintenance-free 15000
Be maintained 30000
Connection mode Horizontal and vertical Horizontal
Net weight(kg) Drawer typetriple/quadrupole 90.5/116 90.5/116 103/130 132/172
Fixed tripole/quad-rupole 55/68 55/68 56.5/71 72/-
Gross weight(kg) Drawer typetriple/quadrupole 105.5/135 105.5/135 118/149 147/191
Fixed tripole/quad-rupole 68/83 68/83 69.5/86 85/-
Arc distance (mm) 0

 

Model number EWK-6300
Rated limit short-circuit break-ing capacity lcu(kA) 120 400V 85 690V
Rated operating short-circuit break-ing capacity lcs(kA) 100 400V 75 690V
Rated short-time withstand currentlcw(kA) 100 400V 75 690V
Rated current In(A) 4000 5000 6300
Number of poles 3,4 3,4 3
Rated voltage U(V) AC400,AC690
Rated insulation voltage Ui(V) 1000
Rated impulse withstandvoltage Uimp(kV) 12
Short-circuit making capacity Icm=264kA AC400V lcm=187kA AC690V
N maximum continuous current In(A) 50%In 50%In
Total breaking,time (no additionaldelay)(ms) ≤28
Closing time(ms) ≤50
Intelligentcontroller Type M/Type H . .
Operatingperformance(sub) Electrical life AC400V:1500, AC690V:1000
Mechanical life maintenance-free 5000
Be maintained 10000
Connection mode Horizontal
Net weight(kg) Drawer typetriple/quadrupole 210/223 210/223 233/-
Gross weight(kg) Drawer typetriple/quadrupole 232/257 232/257 257/-
Arc distance(mm) 0

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
inquiry

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile/WhatsApp
Company Name
Message
0/1000